Black Secure-Lock/P-Lock IEC320 C14 Locking to IEC320 C13 10A 250V

10 Amps250 voltsC14 Locking (P-Lock)C13ULcULRoHSREACH

Reference guide:P-Lock, S-Lock & D-Lock guide →

7

configurations

Not sure which cord you need?

Answer a few quick questions and we’ll narrow it down for you.

Match by picture
ComparePart numberPlugConnectorLengthJacketColourStockPriceAdd to order
14K13-F-012P-LockC14C131 Foot18 AWG · SVTBlack170 in stock $8.75
14K13-F-018P-LockC14C131.5 Feet18 AWG · SJTBlack836 in stock $9.36
14K13-F-024P-LockC14C132 Feet18 AWG · SVTBlack32 in stock $9.36
14K13-F-060P-LockC14C135 Feet18 AWG · SVTBlack494 in stock $13.09
14K13-F-072P-LockC14C136 Feet18 AWG · SVTBlack451 in stock $14.32
14K13-F-084P-LockC14C137 Feet18 AWG · SVTBlack280 in stock $16.68
14K13-F-096P-LockC14C138 Feet18 AWG · SVTBlack151 in stock $16.68

About Black Secure-Lock/P-Lock IEC320 C14 Locking to IEC320 C13 10A 250V

BLACK 10A 250V P-Lock C13 C14 Power Cords. P-Lock power cords are designed to mate with Server Technology, Raritan and Vertiv-Emerson PDUs to securely lock the plug to the PDU. This reduces the chance of accidental power loss to equipment due to vibration and other factors. Cordage is SVT, a thinner cordage than standard duty power cables ideal for high-density data centers. Other colors available include RED, BLUE, YELLOW, and GREEN. 15A Cables also available with a heavier duty, robust SJT jacket. Typical applications: Data Centers, Medical Devices, Automation Industry, Industrial Equipment, Architectural Devices, Broadcasting Stations, and Critical Power Management.

Why use a P-Lock power cord?

P-Lock power cords allow your plug (male) to firmly lock into place on matching Server Technology, Raritan and Vertiv-Emerson PDUs. This eliminates the need to worry about a plug disconnecting from it's PDU due to vibration from equipment or accidental disconnection.

● Revolutionary positive securing system prevents unintentional power disconnection.

● Patented C14 positive mechanism locks with P-Lock outlets and is backward compatible with any standard C13 outlets.

● Fit for high density multi-outlets design

● Rated up to 15 amps● Various colors / lengths available

Standard: IEC 60320

High Potential Test Voltage: 2000VAC (1min 50Hz)

Rating: UL/cUL : 10A/13A/15A 250VAC, VDE : 10A 250VAC

Operation Temperature: -25°C ~ +70°C

Flammability Corresponding to: Plug : UL 94V-2 or better; Cable: UL VW-1, IEC60332-1. Cat F2

Cable Option: North America : 18AWG 3G SVT / 16AWG 3G SJT / 14AWG 3G SJT, Europe : H05VV-F 3G 0.75mm2 / 1.0 mm2

The plugs and connectors in this collection

What each end is, what it mates with, and where to find every cord built on it.

  • IEC 60320 C13 connector

    Connector · IEC 60320

    IEC 60320 C13

    • 15 Amps
    • 125/250V

    On 7 of the cords here

    The IEC 60320 C13 is a grounded 3 Wire connector rated up to 250V and 15 Amps. The C13 mates with a C14 inlet, and is commonly used in a jumper cable scenario in IT Installations providing power from a PDU to a server, router, switch or other computing device. Most people know the C13 as 'the thing that plugs into my computer' because it is the standard connector used to power most desktop computers. In a desktop computer application, the most common cable is the NEMA 5-15P to C13, which connects your standard North American wall outlet to a desktop computer.

    Mates with IEC 60320 C14 Inlet

  • IEC 60320 C14 Locking (P-Lock) plug

    Plug · IEC 60320

    IEC 60320 C14 Locking (P-Lock)

    • 15 Amps
    • 125/250V

    On 7 of the cords here

    The IEC 60320 C14 P-Lock Plug is designed for use with ServerTech and Raritan data center PDUs. The locking tabs on each side prevent the plug head from nuisance unplugging by hooking into the PDU unit. The plug can easily be removed by pressing down on the tabs located on each side.

    Mates with IEC 60320 C13 P-Lock Compatible PDU Outlet

About Black Secure-Lock/P-Lock IEC320 C14 Locking to IEC320 C13 10A 250V

Typical Applications for IEC 60320 P-Lock C14 to C13 Power Cords

Below, the typical application of connecting a Server Technology PDU (Power Distribution Unit)  to a Server, Router, or Switch. This scenario is extremely common in data center environments and in enterprise networking rooms. 

3uiteBAGqAKqiz-p-lock-c14-c13-application-diagram.png

(1) Server Technology Rack Mount PDU Rack Mounted PDUs are the standard way to distribute power to many devices in a rack. P-Lock C14 Plugs are designed to securely lock into place on the PDU, ensuring the cable does not become disconnected to due vibration or other factors.
(2) P-Lock C14 Plug (Male)The P-Lock C14 features tabs on the outside of plug, allowing it lock into a matching receptacle. 
(3) C13 Connector (Female)The C13 connector will mate with a matching C14 inlet, typically found on servers, routers, switches, and your standard desktop computer. 
(4) Server, Router, Switch, Computer, EquipmentMany small appliances use a C14 inlet to provide power to the PSU (Power Supply Unit). Our C13 connectors will mate with any C14 inlet on your small appliance.

10A vs 15A C14 C13 Power Cords

Our 'F' (1413-F-XXX-COL where XXX is the length in inches and COL is the color) series 10A C14 C13 are used to power small IT equipment, typically units that are 1U form factor for rack mounted devices. A typical 1U form factor server contains PSU's operating at < 800w and 120V AC. This means that the max power draw on these is (800W / 120V) = 6.67 amps, safely in the continuous operating range of a 10 amp cable.

Many high-end servers (typically 2U form factor and up), however,  have power supply units that draw more than 1000W per unit. Depending on the operating voltage of the device and your rack setup, this may be greater than the 8 amps max continuous draw allowed for a 10 amp cable. (1000W / 120V = 8.33 amps). In these scenarios, our 'H' C14 C13 series 15 amp power cables would need to be used.

Choosing the correct length

If operating in a data center, or high-density networking closet, it is critical to choose the correct length power cable to increase the efficiency of your installation. Choosing the shortest cable possible for your installation will allow you to reduce line loss (loss of energy due to resistance in the cable) as well as decrease the volume occupied by the cordage. Cubic inches are a hot commodity in high-density racks, by choosing the shortest cable possible you will increase airflow throughout the rack, increasing the efficiency of the PSU's on the server.

Choosing the correct color

Color-coded power cables are typically used to help identify cables in a rack. For example, a red power cable can be used to identify a primary PSU, will a blue power cable can be used to identify a secondary PSU. This can be critical in high availability data centers, where accidentally unplugging the correctly operating primary power supply, instead of the failed secondary power supply, can cost organizations thousands, even millions of dollars. We stock a wide array of Red, Blue, and Black P-Lock power cords and also have yellow and green cords available upon request. 

Current rating

10 Amps

Voltage rating

250 volts

Plug (male end)

IEC 60320 C14 Locking (P-Lock)

Connector (female end)

IEC 60320 C13

Certifications & compliance

  • UL
  • cUL
  • RoHS
  • REACH
  • Every cord we build is hi-pot tested
  • Same-day shipping by 2:30 PM ET
  • NET 30/60/90 for approved accounts
  • In-house engineering and compliance support

Frequently asked questions

What certifications do these power cords carry?
UL and cUL-listed cord sets across the catalog, with 30+ international approval marks (VDE, ENEC, PSE, SAA, CCC, KC and more) on country-specific cords. The approvals each part carries are listed on its product page; documentation is available from sales.
Do you require a minimum order quantity?
No. We sell from 1 cord to 100,000. Volume discounts apply automatically at quantity breaks — you'll see pricing tiers on every product page.
Can I get a custom length or color?
Yes. Custom lengths and non-standard colors are hand-terminated in our Connecticut shop — typically 3–4 business days from in-stock components. Call (860) 763-2100 or submit a quote request with your specs.
How fast does this ship?
In-stock orders placed by 2:30 PM ET ship the same day via FedEx or UPS. All standard configurations are stocked in East Windsor, CT.